Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhao, Yongxiaa | Suo, Hongnab | Wu, Yanmina | Zuo, Ziweia | Zhao, Sisia | Cheng, Shujiea; *
Affiliations: [a] The Affiliated Hospital of Hebei University, Baoding, Hebei Province, China | [b] Medicine School of Hebei University, Baoding, Hebei Province, China
Correspondence: [*] Corresponding author: Shujie Cheng, The Affiliated Hospital of Hebei University, No. 212, Yuhua East Road, Baoding City, Hebei Province 071000, P.R.China. Tel.: +861 5131221591; +861 3933283781; E-mail: shujiecheng@yeah.net.
Abstract: OBJECTIVES:Since body mass index (BMI) affects medical imaging quality or noise due to penetration of the radiation through bodies with varying sizes, this study aims to investigate and determine the optimal BMI-adjusted noise index (NI) setting on the contrast-enhanced liver CT scans obtained using 3D Smart mA technology with adaptive statistical iterative reconstruction (ASIR 2.0) algorithm. MATERIALS AND METHODS:A total of 320 patients who had contrast-enhanced liver CT scans were divided into two equal-sized groups: A (18.5 kg/m2≤BMI<24.9 kg/m2) and B (24.9 kg/m2 ≤ BMI ≤34.9 kg/m2). The two groups were randomly divided into four subgroups with an NI of 11, 13, 15, and 17. All images were reconstructed with 50% ASIR 2.0. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated after the late arterial, portal venous, and equilibrium phases were completed. Images were evaluated by two radiologists using a subjective 0 –5 scale. Mean CT dose index of volume, dose-length product, and effective dose (ED) were calculated and compared using one-way ANOVA. RESULTS:In group A, the best-quality images obtained at the lowest ED were scanned at an NI of 15 in the late arterial phase, and at an NI of 17 in the portal venous and equilibrium phases. In group B, the best results were obtained at an NI of 13 in the late arterial phase, and at an NI of 15 in the portal venous and equilibrium phases. CONCLUSION:Adjusting NI and iterative reconstruction algorithm based on body mass index can help improve image quality on contrast-enhanced liver CT scans, even at low radiation dose.
Keywords: Body mass index, image quality, iterative reconstruction algorithm, noise index, radiation dose
DOI: 10.3233/XST-16222
Journal: Journal of X-Ray Science and Technology, vol. 25, no. 4, pp. 597-611, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl