Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special Issue on Artificial Organs and Regenerative Medicine dedicated to the late Prof. Yukihiko Nosé
Article type: Research Article
Authors: Ündar, Akif; ; | Wang, Shigang
Affiliations: Penn State Hershey Pediatric Cardiovascular Research Center, Department of Pediatrics, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, PA, USA | Department of Surgery and Bioengineering, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, PA, USA
Note: [] Address for correspondence: Akif Ündar, Professor of Pediatrics, Surgery and Bioengineering, Department of Pediatrics, Penn State Hershey College of Medicine, H085 500, University Drive, P.O. Box 850, Hershey, PA 17033-0850, USA. Tel.: +1 717 531 6706; Fax: +1 717 531 0355; E-mail: aundar@psu.edu
Abstract: Extracorporeal life support (ECLS) and mechanical circulatory support (MCS) have become indispensable treatment tools for pediatric patients with congenital heart defects undergoing peri-operative or end-stage heart and/or lung failure. ECLS and MCS can serve as bridges to recovery, transplantation (heart or lung), destination therapy, or “bridge to bridge” long-term MCS. Dependent on patient condition, venoarterial ECMO (V-A ECMO) for heart and lung support, venovenous ECMO (V-V ECMO) for respiratory support, and MCS for uni- and biventricular support can be selected properly. Considering small patient body size, the access sites and cannulation should be selected carefully to obtain adequate blood flow, minimum injury, and easy management. The applying equipment, including tubing, cannulae, oxygenator and blood pump, need to be selected optimally in order to enable rapid setup and priming, successful cannulation and early support, and to reduce the risk of device-related morbidity and mortality. The aim of this review manuscript was to discuss briefly the current devices for pediatric ECLS and MCS available in US.
Keywords: ECLS, MCS, pediatrics
DOI: 10.3233/BME-120732
Journal: Bio-Medical Materials and Engineering, vol. 23, no. 1-2, pp. 57-62, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl